How to Set the Emergency Alarm Function of HA1G

  • Posted by:Sunny
  • 0 Comments
How to Set the Emergency Alarm Function of HA1G

When you encounter an emergency situation, the alarm function of the walkie-talkie will help you to contact your companion as soon as possible. HA1G has a very powerful alarm function, today we will learn about the alarm function of HA1G together.

Alarm flow:Alarm duration---Hot MIC time---Reception time(one cycle). This is a complete alarm flow.

Alarm System Name: You can name an alarm channel.

channel named

The part of setting directly with Radio

1. Alarm type selection.

Alarm function

Siren Only: Only the unit sounds, not related to the alarm mode.

Regular: The unit has sound and light alerts, the alarm process is determined by the alarm mode.

Silent: There is no sound and light prompts, the unit does not receive voice (does not open the speaker), the alarm process is controlled by the alarm mode.

Secret W/Voice: there is no sound and light prompts, the machine receives voice, the alarm process is controlled by the alarm mode.

2. Alarm Mode selection.

energency alarm function

① Emg Alarm: only for the process of the alarm duration

② Emergency W/Call: no alarm duration, only hot MIC time and receiving time

Emg Alarm W/Call: complete alarm process

3. Specify the hopping channel selection.

Select the alarm channel

4. Attribute Settings.

Native Alarm Tone Tone On/Off. (Only works in regular alarm type; all other alarm types can not set local alarm tone on/off, display gray, local alarm tone on/off is determined by the alarm type)

Parts that need to be set with programming software:

1. Alarm sub-tone mode; you can choose carrier or sub-tone/sub-tone digital;

If you choose carrier, then you need to receive the alarm machine to turn off the sub-tone, as long as the frequency and HA1G transmitting alarm channel frequency is the same as the hot MIC voice can be received;

If you choose sub-tone/sub-tone digital, then you need to receive the sub-tone frequency set by the machine receiving the alarm to be consistent with the sub-tone frequency of the HA1G transmitting alarm channel to receive the hot MIC voice;

2. Alarm Duration: the duration of the alarm tone;

3. Hot MIC time: the time when the microphone is turned on after the alarm.

4. Alarm cycle: the end of the alarm process is a period of time.

After reading this if you are still a little confused, you can watch our related video operation!

https://www.youtube.com/watch?v=GoPNYzS3i7g